Real-time ambient air quality monitoring and dust management for active construction environments.
Construction sites are among the most significant sources of localised ambient air quality degradation in Indian urban areas. Earthmoving, demolition, concrete batching, diesel equipment and material handling generate PM2.5 and PM10 at levels that regularly exceed National Ambient Air Quality Standards (NAAQS) thresholds. In most sites, there is no continuous monitoring in place, no automated alert system and no documented compliance record.
This creates regulatory exposure for project developers and contractors, and reputational risk for projects seeking green building certification where construction-phase IAQ management is a documented requirement.
PM1.0, PM2.5, PM10, CO, NO₂, SO₂, TVOC, temperature, humidity and wind speed. Sensors positioned at site perimeter and downwind boundaries, capturing emissions as they leave the site rather than only at the source.
Configurable alerts tied to NAAQS thresholds and project-specific dust management trigger levels. Notifications sent to site managers, HSE teams and project directors without delay.
Continuous data logged and structured for submission to pollution control authorities, green building certification bodies and corporate ESG reporting frameworks.
LoRa and cellular connectivity for sites without fixed network infrastructure. Solar power options available for remote locations. No dependency on site internet.
For developers managing concurrent projects, all sites visible in a single dashboard. Exceedances flagged by site and parameter.
Parameters monitored
10 to 13, including PM, gases and meteorological
Alert response time
Real-time, configurable by threshold
Compliance documentation
Continuous, structured for CPCB and certification bodies
| Metric | Observed Range |
|---|---|
| Parameters monitored | 10 to 13, including PM, gases and meteorological |
| Alert response time | Real-time, configurable by threshold |
| Compliance documentation | Continuous, structured for CPCB and certification bodies |
| Connectivity | Wi-Fi, LoRa or cellular, no fixed network required |
A site scoping exercise identifies boundary monitoring locations, applicable regulatory thresholds and the data infrastructure required for continuous, audit-ready compliance documentation.
A structured site assessment identifies compliance gaps, energy losses and the remediation options available - before your next audit cycle.